Application Farmland irrigation
River drainage
Deep well pumping
Industrial sewage
Sewage drainage
Domestic waste water
Municipal sewage treatment,
Construction engineering, pond, textile ,sewage discharge
Transport of mud, domestic waste water, sewage.
Operating Conditions Liquid temperature up to: 35° C
Max.AMBIENT Temperature: 40° C
Max.Immersed depth: 5m
Liquid PH vatue: 4-10
Liquid Kinematic : 7x10 -7¬ 23x10 -6m2/s
Max.Liquid density: 1.2x103kg/m3
insulation class: B/F
Protection class: IPx8
Materials Housing: Cast iron
Impeller: Iron
Shaft: AISI304
Mechanical seal: 5Ceramic/Graphite
Built-in protector& Double sealing structure
With float switch and 8m Cable
110V/127V/220V/380V440V,50Hz/60Hz available
Using Conditions The working medium is non-corrosive clean water, the volume ratio of sand content in the medium does not exceed 0.1%, the particle size is not greater than 0.2MM.
The medium temperature does not exceed 40oC
The PH of the medium is set at 6.5-8.5. The electric pump is used within the rated lift range.The electric pump should be fully immersed in the water to prevent it from burning .